High-temperature electric control valves are similar to single-seat valves except that the valve body is high-temperature and high-pressure. Its characteristics dictate a simple path of movement and low resistance. This can result in a particularly high pressure drop. Preparation of high viscosity fluids, suspended solids and particulate matter. Prevents coking, sticking and clogging, and is easy to clean and self-cleaning.
High-temperature electric control valve use matters for attention
1, positive and negative use comparison: general high temperature electric control valve is installed in the positive direction, that is, the lower inlet side outlet. Only in the differential pressure, high viscosity, easy coking, suspended particulate matter is recommended to reverse installation. That is, the material in and out of the bottom. The goal of using high temperature electric control valve in reverse direction is to improve the unbalance force and cut down the spool wear. In addition, it has high viscosity, easy coking, and agitation containing suspended particles of activity. Prevent coking and clogging of the medium.
2, high temperature electric control valve reverse use analysis: Jilin Chemical Co., Ltd. from West Germany's acetaldehyde device bailed out the use of pv-23404 high temperature electric control valve. Reverse in the high-pressure landing process premise. Water system trial run process, high temperature electric control valve vibration intense, noise. After 4 hours of trial operation, the valve spool was damaged. At that time, the international experts feel that the spool quality is poor into. The author feels that it is not a quality problem, but improper use. The reasons for the breakage are analyzed as follows. We know that the other structure of the regulating valve are asymmetric, except for the butterfly valve and the partition valve, they are symmetric in structure. When the regulating valve transforms the flow direction, the value changes due to the change of the flow path.
3, high temperature electric adjustment valve flow path is simple, resistance is small, generally applicable to positive use (installation). However, in the environment of large pressure drop, it is recommended to use high temperature electric adjustment valve in the reverse direction. This improves the unbalanced force, cuts down the damage to the spool, while utilizing the medium to prevent coking and clogging of the grasp valve. High-temperature electric control valves can be used in the reverse direction to prevent damage to the spool from strong vibration. Especially in the prototype stage of the chemical manufacturer, it is important to avoid a state of perpetual openness. Due to the small load in the trial production, can not quickly arrive at the planned process prerequisites, take the electric control valve. Avoid intrusion in the opposite direction only. Small openings are opened for a long time to prevent damage to the thermoelectric control valve.
Paradigm regulating valves of the normal flow direction is the direction of the spool open (counter use), the manufacturer only provides the flow value and flow characteristics of the normal flow direction. When the regulating valve is used in the reverse direction, the flow rate of the regulating valve increases as the fluid moves in the direction of the closed spool. Carry out the water coupling test, can not be boarded to arrive at the simulation process prerequisites, the regulating valve is used for a long time, the opening degree is small, the force is not balanced to cause tension instability.