Pneumatic Fluorine Lined Control Valve Maintenance Procedures

1, fluorine lined control valve flushing: to flush the media harmful to health, we must first understand its characteristics, and then select the appropriate flushing method.

2, fluorine lined control valve destruction: destruction of the valve, to protect the seat, spool, stem and push rod processing surface.

3, spool, seat: sealing surface wear is small, can be machined to repair. If the damage is intense, it needs to be replaced.

4, valve stem: surface damage, can only be replaced with a new one.

5、Push rod and guide sleeve sealing surface damage: need to replace the counteracting actuator, the ability to use positive actuator after repair.

6、Compression spring: if there are still cracks or other bad parts that affect the strength, it needs to be replaced.

7, wearing parts: packing, gasket, O-ring. These are replaced at each overhaul. The spacer should be checked for signs of fragmentation, aging and corrosion. The test results determine whether to replace, but the service life of the partition is usually longer, 2-3 years.

8, pneumatic fluorine lined adjustment valve in the assembly, pay attention to centering. The bolts should be tightened at an angle and the slider should be lubricated. After the assembly is realized, it should be debugged according to the method of the factory test project of the product. In this era, packing compression force, spool closing position and valve positioner can be mediated.